Huona (Shanghai) New Material Co., Ltd.
Shanghai, China
Diamond Member Since 2016
Audited Supplier
Manufacturer/Factory
Sample Available
OEM/ODM Service
Factory Tour
Manufacture K Type Thermocouple Wires Used for Thermocouple Sensors
Purchase Qty.: (Meter) |
1-19 20-99 100+ |
---|---|
Reference FOB Unit Price: | US $0.06 US $0.45 US $0.79 |
Application: | Electronics, Industrial, Medical, Chemical |
---|---|
Standard: | JIS, DIN, AISI, ISO9001 |
Purity: | Chromel Alumel |
Alloy: | Alloy |
Type: | Nickel Wire |
Powder: | Wire |
Basic Info
Model NO.
K
Item
K Type Thermocouple Alloy Wires Used for Thermocou
Conductor
Chromel Alumel
Surface
Bright or Oxidized Thermocouple Wire
Leading Time
7 Days or So
Free Sample
Available
MOQ
5 Kg Each
Tensile Strength
More Than 390
Kp
Chromel
Wire Shape
Round/Flat
Kn
Alumel
Dia
0.3/0.5/0.8/1.0/1.2/1.6/2.0/2.5/3.2mmm
Grade
I/II/III
Us Grade
Tc Wire / K14 Thermocouple Wire
OEM
Yes
Stock
Seyn
Transport Package
Carton Box for Thermocouple Wire
Specification
SGS
Trademark
HUONA
Origin
China
HS Code
7505220000
Production Capacity
1000 Tons/Year
Product Description
K Type Thermocouple Alloy Wires Used For Thermocouple sensors
--huonar.en.made-in-china.com
Description :
K Type Thermocouple Wire is the most common type of thermocouple. It's inexpensive, accurate, reliable, and has a wide temperature range.
The type K is commonly found in nuclear applications because of its relative radiation hardness. Maximum continuous temperature is around 1,100C.
Type K Temperature Range:
Thermocouple grade wire | -454 to 2,300F (-270 to 1260ºC) |
Extension wire | 32 to 392F (0 to 200ºC) |
Type K Accuracy (whichever is greater):
--Standard: +/- 2.2C or +/- .75%
--Special Limits of Error: +/- 1.1C or 0.4%
Consideration for bare wire type K thermocouple applications:
--The Type K is made with two alloys of high nickel content which allows their use in both oxidizing and reducing atmospheres
--It is necessary to take the precautions when reducing atmospheres.
Types of thermocouple extension wire
Thermocouple Code | Comp. Type | Comp. Wire Name | Positive | Negative | ||
Name | Code | Name | Code | |||
K | KCA | Iron-constantan22 | Iron | KPCA | Constantan22 | KNCA |
K | KCB | Copper-constantan 40 | Copper | KPCB | Constantan 40 | KNCB |
K | KX | Chromel10-NiSi3 | Chromel10 | KPX | NiSi3 | KNX |
Nominal chemical composition
Name of Wire | Grade | Nominal Composition /% | |||||
Cu | Ni | Cr | Si | Fe | Mg | ||
Fe-CuNi22 | KPCA | - | - | - | - | 100 | - |
Cu-Ni 40 | KPCB | 60 | 40 | - | - | - | - |
Ni-Cr 10 | KPX | - | 90 | 10 | - | - | - |
Specification of alloy wire
Dia of Wire/mm | The number of core strands | Nominal cross-sectional area/mm2 |
0.20 | 7 | 0.2 |
0.30 | 7 | 0.5 |
0.41 | 19 | 2.5 |
0.43 | 7 | 1.0 |
0.52 | 7 | 1.5 |
0.52 | 1 | 0.2 |
0.80 | 1 | 0.5 |
1.13 | 1 | 1.0 |
1.38 | 1 | 1.5 |
1.78 | 1 | 2.5 |
Thermal EMF range and tolerance
Graduation | Grade | Measuring temperature/ºC | Nominal value/μV | Class 1 | Class 2 | |||
Tolerance μV | Thermal EMF Range μV | Tolerance μV | Thermal EMF Range μV | |||||
K | KX,KCA,KCB | G | -25 | -968 | ±44 | -924~-1012 | ±88 | -880~-1056 |
100 | 4096 | 4052~4140 | 4008~4184 | |||||
K | KX KCA | H | -25 | -968 | ±44 | -924~-1012 | ±88 | -880~-1056 |
100 | 4096 | 4052~4140 | 4008~4184 | |||||
200 | 8138 | 8094~8182 | 8050~8226 |