Manufacture Thermocouple Compensation Cable Type K Nicr-Nickel Silicon

Product Details
Customization: Available
Classification: Insulated
Section Area: 0.5mm2

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, QC 080000
OEM/ODM Availability
Yes
  • Manufacture Thermocouple Compensation Cable Type K Nicr-Nickel Silicon
  • Manufacture Thermocouple Compensation Cable Type K Nicr-Nickel Silicon
  • Manufacture Thermocouple Compensation Cable Type K Nicr-Nickel Silicon
  • Manufacture Thermocouple Compensation Cable Type K Nicr-Nickel Silicon
  • Manufacture Thermocouple Compensation Cable Type K Nicr-Nickel Silicon
  • Manufacture Thermocouple Compensation Cable Type K Nicr-Nickel Silicon
Find Similar Products

Basic Info.

Model NO.
type k
Grade
I, II
Usage
Thermocouple Sensors
Types
K
Shape
Single, Pair, Stranded
Insulation
Fiberglass
Shield
Avaiable
Colour
IEC, BS
Surface
Bright/ Oxidized Thermocouple Wire
Mainly Usage
Measure The Temperature of Molten Steel
Wire Shape
Round/Flat
Transport Package
on Reel, Carton Box
Specification
7*0.3mm
Trademark
HUONA
Origin
Shanghai
HS Code
8544421900
Production Capacity
3000 Tons/Year

Product Description

Thermocouple Compensation Cable Type  K

    NiCr-Nickel Si (Type K) thermocouple finds the widest use in all basemetal thermocouple, at temperature above 500 °C.

Type K thermocouple has strong resistance to oxidation than other base metal thermocouples. It has high EMF against Platinum 67, excellent temperature accuracy, sensitivity and stability, with a low cost. It is recommended for oxidizing or inert atmospheres, but cannot be used directly in the following cases:

1.Alternatively oxidizing and reducing atmosphere.
2.Atmosphere with sulphur gases.
3.Long time in vacuum.
4.Low oxidizing atmosphere such as hydrogen and carbon monoxide atmosphere.
 

Detailed Parameter

Diameter/mm Long time Working temperature /ºC Short period Working temperature /ºC
0.3 700 800
0.5 800 900
0.8,1.0 900 1000
1.2,1.6 1000 1100
2.0,2.5 1100 1200
3.2 1200 1300

Application:

1.Heating - Gas burners for ovens
2.Cooling - Freezers
3.Engine protection - Temperatures and surface temperatures
4.High temperature control - Iron casting
 

Type K Thermocouple Bare Wire

Type K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures.

1. Chemical Composition

Material Chemical composition (%)
Ni Cr Si Mn Al
KP(Chromel) 90 10      
KN(Alumel) 95   1-2 0.5-1.5 1-1.5

2. Physical properties and Mechnical properties

Material

Density(g/cm3)

Melting point(ºC)

Tensile Strength(Mpa)

Volume resistivity(μΩ.cm)

Elongation rate (%)

KP(Chromel) 8.5 1427 >490 70.6(20ºC) >10
KN(Alumel) 8.6 1399 >390 29.4(20ºC) >15

3. EMF Value range at different temperature

Material EMF value Vs Pt(μV)
100ºC 200ºC 300ºC 400ºC 500ºC 600ºC
KP(Chromel) 2816~2896 5938~6018 9298~9378 12729~12821 16156~16266 19532~19676
KN(Alumel) 1218~1262 2140~2180 2849~2893 3600~3644 4403~4463 5271~5331
EMF value Vs Pt(μV)
700ºC 800ºC 900ºC 1000ºC 1100ºC
22845~22999 26064~26246 29223~29411 32313~32525 35336~35548
6167~6247 7080~7160 7959~8059 8807~8907 9617~9737

 

Type K Extension Cable Chromel / Alumel Material FEP insulation

Specifications

1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.

Thermocouple variety and index


Thermocouple Variety and Index

Variety

Type

Measurement Range(°C)

NiCr-Nickel Si

K

-200-1300

NiCr-CuNi

E

-200-900

Fe-CuNi

J

-40-750

Cu-CuNi

T

-200-350

NiCrSi-Nickel Si

N

-200-1300
NiCr-AuFe0.07 NiCr-AuFe0.07
-270-0
 

3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire

 Dimensions / Tolerance mm ) : 4.0+-0.25

Color code & initial calibration tolerances for thermocouple wire:

Thermocouple Type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
CHROMEL(+) vs.
ALUMEL(-)
K Yellow/Red Brown -200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C
± 2%
±2.2°C
±2.2°C
± .75%
±1.1°C
± .4%


Color Code & Initial Calibration Tolerance for Extension Wire:

Extension type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron (+) vs. Constantan(-) JX White/Red Black 0°C to +200°C ±2.2°C ±1.1°C
CHROMEL (+) vs. ALUMEL (-) KX Yellow/Red Yellow 0°C to +200°C ±2.2°C ±1.1°C
Copper(+) vs. Constantan(-) TX Blue/Red Blue -60°C to +100°C ±1.1°C ± .5°C
CHROMEL(+) vs. Constantan(-) EX Purple/Red Purple 0°C to +200°C ±1.7°C ±1.1°C


PVC-PVC Physical Properties:

Characteristics Insulation Jacket
Abrasion Resistance Good Good
Cut Through Resistance Good Good
Moisture Resistance Excellent Excellent
Solder Iron Resistance Poor Poor
Service Temperature

105ºC continuous

150ºC single

105ºC continuous

150ºC single

Flame Test Self-extinguishing Self-extinguishing
 

Manufacture Thermocouple Compensation Cable Type K Nicr-Nickel Silicon

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now