Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | 0.3mm |
Still deciding? Get samples of US$ 20/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Thermocouple grade wire | -454 to 2,300F (-270 to 1260ºC) |
Extension wire | 32 to 392F (0 to 200ºC) |
Thermocouple Code |
Comp. Type |
Comp. Wire Name |
Positive. | Negative | ||
Name | Code | Name | Code | |||
K | KCA | Iron-constantan22 | Iron | KPCA | Constantan22 | KNCA |
K | KCB | Copper-constantan 40 | Copper | KPCB | Constantan 40 | KNCB |
K | KX | Chromel10-NiSi3 | Chromel10 | KPX | NiSi3 | KNX |
Name of Wire | Grade | Nominal Composition /% | |||||
Cu | Ni | Cr | Si | Fe | Mg | ||
Fe-CuNi22 | KPCA | - | - | - | - | 100 | - |
Cu-Ni 40 | KPCB | 60 | 40 | - | - | - | - |
Ni-Cr 10 | KPX | - | 90 | 10 | - | - | - |
Dia of Wire/mm | The number of core strands | Nominal cross-sectional area/mm2 |
0.20 | 7 | 0.2 |
0.30 | 7 | 0.5 |
0.41 | 19 | 2.5 |
0.43 | 7 | 1.0 |
0.52 | 7 | 1.5 |
0.52 | 1 | 0.2 |
0.80 | 1 | 0.5 |
1.13 | 1 | 1.0 |
1.38 | 1 | 1.5 |
1.78 | 1 | 2.5 |
Graduation | Grade | Measuring temperature/ºC | Nominal value/μV | Class 1 | Class 2 | |||
Tolerance μV |
Thermal EMF Range μV |
Tolerance μV |
Thermal EMF Range μV |
|||||
K | KX,KCA,KCB | G | -25 | -968 | ±44 | -924~-1012 | ±88 | -880~-1056 |
100 | 4096 | 4052~4140 | 4008~4184 | |||||
K | KX KCA |
H | -25 | -968 | ±44 | -924~-1012 | ±88 | -880~-1056 |
100 | 4096 | 4052~4140 | 4008~4184 | |||||
200 | 8138 | 8094~8182 | 8050~8226 |