Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Classification: | Type N |
| Modle No.: | Nx |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Thermocouple type | Extension condution model | Extension condution alloy wire | |||||||||||
| N | NX | Name | Code | Polarity | Chemical Composition/% | Density (g/cm3) | Resistivity (μΩ.cm) |
Tensile Strength (Mpa) |
|||||
| Ni | Cr | Si | Mg | ||||||||||
| Ni-Cr14-Si | NPX | Positive | 84 | 14.5 | 1.5 | - | 8.7 | <7.9 | >490 | ||||
| Ni-Si4-Mg | NNX | Nagative | 94.5 | - | 4.5 | 1.0 | 8.6 | <0.3 | >390 | ||||
| Alloy wire Dia/mm |
Apply to the number of wire cores | The nominal cross-sectional area of the wire core /mm² |
| 0.2 | 7 | 0.2 |
| 0.3 | 7 | 0.5 |
| 0.41 | 19 | 2.5 |
| 0.43 | 7 | 1.0 |
| 0.52 | 7 | 1.5 |
| 0.52 | 1 | 0.2 |
| 0.8 | 1 | 0.5 |
| 1.13 | 1 | 1.0 |
| 1.38 | 1 | 1.5 |
| 1.78 | 1 | 2.5 |
| Thermocouple type | Extension condution model | Use classification | Operating temperatures/°C |
Nominal value of thermoelectric EMF |
Level I | |
| Tolerance | Range of EMF | |||||
N |
NX NC | G | -25 | -646 | ±43 | -603 ~ -689 |
| 100 | 2774 | 2 731 ~ 2 817 | ||||
N |
H | -25 | -646 | ±43 | -603 ~ -689 | |
| 100 | 2774 | 2 731 ~ 2 817 | ||||
| 200 | 5913 | 5 870 ~ 5 956 | ||||