Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire

Product Details
Customization: Available
Certification: ISO9001, CCC
Conductor Material: Nicr-Nial
Still deciding? Get samples of US$ 20/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, QC 080000
OEM/ODM Availability
Yes
  • Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
  • Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
  • Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
  • Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
  • Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
  • Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
Find Similar Products

Basic Info.

Model NO.
Type K
Sheath Material
PVC
Plug Type
European-Standard Plug
Insulating Materials
PTFE
Section Area
0.5mm2, 0.75mm2, 1.0mm2
Grade
I, II, III
Usage
Thermocouple Sensors
OEM
Yes
Types
K,T,J,N,B,S,R
Shape
Single, Pair, Stranded
Insulation
Fiberglass, PVC, PTFE, Silicon Rubber
Temperature Range
-60-1100
Shield
Avaiable
Colour
IEC, Ansl, BS
Transport Package
Wooden Case or Carton
Trademark
SHUONA
Origin
Shanghai
HS Code
7505220000
Production Capacity
1000 Tons/ Year

Product Description

Type K Chromel Alumel Thermocouple Wire NiCr/NiAl Heating Alloy Wire

A thermocouple is a temperature measuring device consisting of two conductors of dissimilar metals or alloys that are connected only at the ends. When the ends are at different temperatures a small voltage is produced in the wire that can be related directly to the temperature difference between the ends. If the temperature at one end is known, the temperature at the other end can be determined. 

HUONA Thermocouple wire or extension grade wire is recommended to be used to connect thermocouples to the sensing or control instrumentation. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response, and service life should be considered. 

HUONA Thermocouple temperature range and tolerance
Type Standard Operating temperature range (°C) Tolerance(°C)
Long term Short term Grade Temperature range Tolerance
Type K GB/T2614 K 1200 1300 I -40~1100 ±1.5°C/±0.4%t
II -40~1300 ±2.5°C/±0.75%t
Type N GB/T17615 N 1200 1300 I -40~1100 ±1.5°C/±0.4%t
II -40~1300 ±2.5°C/±0.75%t
Type E GB/T4993 E 750 900 I -40~800 ±1.5°C/±0.4%t
II -40~900 ±2.5°C/±0.75%t
Type J GB/T4994 J 600 750 I 0~750 ±1.5°C/±0.4%t
II ±2.5°C/±0.75%t
Type T GB/T2903 T 300 350 I -40~350 ±0.5°C/±0.4%t
II ±1°C/±0.75%t
III -200~40 ±1°C/±1.5%t
 
 
HUONA THERMOCOUPLE ALLOYS CHARACTERISTICS:
1)Manufactured according to international quality. System (ISO9001)  IEC584-1 IEC584-2 standard
 
2)Stable EMF and long-life span
 
3)Mill test certificate will be provided after production
 
4)Size range  wire:0.05-10mm  ribbons: 0.05-0.2*2-6mm  strips: 0.05-5*5-250mm
 
5)Good packing methods to keep goods no damage during delivery
 
6)Customized lable, packing, OEM service
 
7)24 hours after-sale service

 
HUONA MAIN CHARACTERISTICS OF WISDOM THERMOCOUPLE ALLOYS
TYPE J (Iron vs Constantan) is used in vacuum, oxidizing, inert or reducing atmospheres. Iron element oxidizes rapidly at temperatures exceeding 538'C, and therefore heavier gauge wire is recommended for longer life at these temperatures. 

TYPE K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures. 

TYPE T (Copper vs Constantan) is used or service in oxidizing, inert or reducing atmospheres or in vacuum. It is highly resistant to corrosion from atmospheric moisture and condensation and exhibits high stability at low temperatures. It is the only type with limits of error guaranteed for cryogenic temperatures.

TYPE E (CHROMEL vs Constantan) may be used in oxidizing, inert or dry reducing atmospheres, or for short periods of time under vacuum. Must be protected from sulfurous and marginally oxidizingatmospheres. Produces the highest EMF per degree o any standardized thermocouple.

Type N thermocouple (Ni Cr Si-Ni Si Mg)  is the latest base metal thermocouple, developed to improve the drawbacks that type K thermocouple has. The main chemical composition of positive leg Nicrosil(NP) is Ni: Cr: Si≈84.4: 14.2: 1.4; negative leg Nickel si (NN) is Ni: Si: Mg≈95.5: 4.4: 0.1. Type N thermocouple also be used in the similar atmospheres that type K works, and the operating temperature range is -200~1300 °C.
 

WHY CHOOSE HUONA NICR HIGH QUALITY THERMOCOUPLE ALLOYS?
All our raw material is made from prime material, not recycle material. We have more than 25 years experience in manufacturing thermocouple alloys.
In the market, not all the Thermocouple alloys are with standard chemical composition and stable EMF. Professional and reliable is the soul of our business.

Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire
Type K Chromel Alumel Thermocouple Wire Nicr/Nial Heating Alloy Wire









 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier